Row Fogo Centre for Research into Ageing and the Brain
Row Fogo Centre for Research into Ageing and the Brain Logo

New publication in BMC Ophthalmology

Publication date: February 2022

Publication title: "Measuring axial length of the eye from magnetic resonance brain imaging"
Authors: Wiseman, S.J., Tatham, A.J., Meijboom, R. , Muniz Terrera, G., Hamid, S., Doubal, F. N., Wardlaw, J. M., Ritchie, C., Dhillon, B. & MacGillivray, T.

 

Abstract

Background

Metrics derived from the human eye are increasingly used as biomarkers and endpoints in studies of cardiovascular, cerebrovascular and neurological disease. In this context, it is important to account for potential confounding that can arise from differences in ocular dimensions between individuals, for example, differences in globe size.

Methods

We measured axial length, a geometric parameter describing eye size from T2-weighted brain MRI scans using three different image analysis software packages (Mango, ITK and Carestream) and compared results to biometry measurements from a specialized ophthalmic instrument (IOLMaster 500) as the reference standard.

Results

Ninety-three healthy research participants of mean age 51.0 ± SD 5.4 years were analyzed. The level of agreement between the MRI-derived measurements and the reference standard was described by mean differences as follows, Mango − 0.8 mm; ITK − 0.5 mm; and Carestream − 0.1 mm (upper/lower 95% limits of agreement across the three tools ranged from 0.9 mm to − 2.6 mm). Inter-rater reproducibility was between − 0.03 mm and 0.45 mm (ICC 0.65 to 0.93). Intra-rater repeatability was between 0.0 mm and − 0.2 mm (ICC 0.90 to 0.95).

Conclusions

We demonstrate that axial measurements of the eye derived from brain MRI are within 3.5% of the reference standard globe length of 24.1 mm. However, the limits of agreement could be considered clinically significant. Axial length of the eye obtained from MRI is not a replacement for the precision of biometry, but in the absence of biometry it could provide sufficient accuracy to act as a proxy. We recommend measuring eye axial length from MRI in studies that do not have biometry but use retinal imaging to study neurodegenerative changes so as to control for differing eye size across individuals.

 

Publication link

Publication link (external website)

Related links

Row Fogo Centre - Publications